Figure 6-75
2000-sheet Input Tray Rollers: Pickup, Feed, and Separation
To Remove the Feed and Separation Rollers
1 2 Open the Vertical Transfer Unit (VTU) on the 2000-sheet Input Tray. Locate the rollers inside the tray cavity. To remove a roller, pinch the retainer tabs together and slide the roller off the shaft. Remove the Feed Roller (upper-rear roller) first. Then remove the Separation Roller (lower roller).
To Remove the Pickup Roller
1 2 3 4 Open the paper tray on the 2000-sheet Input Tray to the stops. Remove the Left Cover from the 2000-sheet Input Tray (see figure 6-66 on page 339). Locate the Pickup Roller inside the tray cavity. Pinch the recessed retainer tab on the roller, and slide the roller off the shaft.
Note
Reassembly notes are on the next page.
C4265-909072000-sheet Input Tray Removal and Replacement 355